Model Suffix Glossary
F - |
Flush mount |
I - |
Internal mount |
P - |
Pressure test against water leaks. |
S - |
Corrosion resistant coating |
SC - |
Corrosion resistant coating core only |
SH - |
Corrosion resistant coating on housing only |
SS - |
Stainless Steel Housing |
ST - |
Stainless Steel In/Outlets ( air to water ) |
SAC - |
Stainless Steel coils aluminum fins ( air to water ) |
HL - |
External Hazardous Location Fan (purge unit) Div 2 |
HL2- |
Hazardous Location Fan (non purge) Div 2 |
XP - |
Hazardous Location (unit with blower) Div 1 & 2 |
Type 12 - |
UL type 12 NEMA 12 |
Type 4 - |
UL type 4 NEMA 4 |
Type 4X - |
UL type 4X NEMA 4X ( air to water ) |
CE - |
European safety standard ( Communiqué European ) |
RH - |
Rain hood ( flush Air to Air mount units ) UL Type 3R |
W - |
Wash Down Fan |
WL - |
Wet location fan (UL recognized for hosedown) |
WL - RH |
WL fan and rain hood (type 4/outdoor) |
NP - |
Custom |
NF - |
No-fans |
NIF - |
No inside fan |
NOF - |
No outside fan |
RF - |
Reversed fan |
RIF - |
Reversed inside fan |
ROF - |
Reversed outside fan |
- NEMA DESIGNATIONS
The National Electrical Manufacturer’s Association (NEMA) has developed a set of standards for the Electrical Industry to assist the user and the manufacturer in the identification and the standardization of many electrical components.
- NEMA Type 1- General Purpose indoor. Type 1 enclosures are intended for use INDOORS, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service conditions do not exist.
- NEMA Type 12- Dust tight, drip tight. Type 12 enclosures are intended for use INDOORS to protect the enclosed equipment against falling non-corrosive liquids and falling dirt.
- NEMA Type 3-Dustight, Raintight and Sleet/Ice Resistant Outdoor. Type 3 enclosures are intended for use OUTDOORS to protect the enclosed equipment against windblown dust and water.
- NEMA Type 3R- Raintight and Sleet/Ice Resistant Outdoor. Type 3R enclosures are intended for use OUTDOORS to protect the enclosed equipment against rain and meet the requirements of Underwriters’ Labs UL508 applying to “Rainproof Enclosures”.
- NEMA Type 4- Watertight and Dusttight Indoor and Outdoor. Type 4 enclosures are intended for use INDOORS or OUTDOORS to protect the enclosed equipment against splashing water, seepage of water, falling or hose directed water, and severe external condensation.
- NEMA 4X- Watertight, Dust tight and Corrosion Resistant Indoor and Outdoor. Type 4X enclosures have the same protection and provisions as Type 4 enclosures, and in addition, are corrosion- resistant.