Hazardous Location
Using fans suitable for combustible environments, Noren Products offers air-to-air and air-to-water models for use in hazardous locations including Class I and II, Division 1 and 2 classifications. In both purge and non-purge applications where water is available for cooling, our air to water units are the ideal low cost, low maintenance solution. (Unit will not maintain NEMA 7 type enclosures.)
|
Typical applications |
|
|
Class I
|
Class II
|
New XP FANS
- New XP fans now available for Class 1, Div 2 Group A,B,C and D are available for sale as a stand alone product or with the following heat exchangers in purged or non-purged applications:
Purged and non-purged applications:
- AIR-to-AIR
CC500P, CC800P, CC1200P, CC1400P, CC2000P, CC600FP, CC900FP, CC1300FP, CC2500FP CC4000FP See Use Table - AIR-to-WATER
CC3060P, CC3260P CC6360P See Use Table
Purged applications only use:
- AIR-to-WATER CC2060P See Use Table
- AIR-to-AIR CC851-XP, CC1251-XP See Use Table
| DIVISION 1 (Hazard is normally present) |
DIVISION 2 (Hazard is not normally present) |
||||||||||
| Purge Type → | X purge | Y purge | Z purge | None (no purge) | |||||||
| Cabinet Cooler Type * → | XP | A/W | XP + IHL | A/W + IHL | XP | A/W | HL | XP + IHL | A/W + IHL |
HL2 |
|
| CLASS 1 | |||||||||||
| GROUP A: Acetylene | No | 2060P 3060P 3260P 6360P | No | 3060P-IHL, 3260P-IHL, 6360P-IHL | No | 2060P 3060P 3260P 6360P | CC500, 800, 1200, 1400, & 2000 P-HL. CC600F, 900F, 1300F, 2500F, & 4000FP-HL | No | 3060P-IHL, 3260P-IHL, 6360P-IHL |
CC500, 800, 1200, 1400, & 2000 P-HL2. CC600F, 900F, 1300F, 2500F, & 4000F P-HL2 |
|
| GROUP B: Hydrogen, Manufactured Gas, etc. | No** | 2060P 3060P 3260P 6360P | No** | 3060P-IHL, 3260P-IHL, 6360P-IHL | No** | 2060P 3060P 3260P 6360P | CC500, 800, 1200, 1400, & 2000 P-HL. CC600F, 900F, 1300F, 2500F, & 4000FP-HL | No** | 3060P-IHL, 3260P-IHL, 6360P-IHL |
CC500, 800, 1200, 1400, & 2000 P-HL2. CC600F, 900F, 1300F, 2500F, & 4000F P-HL2 |
|
| GROUP C: Diethyl ether, ethylene, cyclopropane, etc. | 851XP 1251XP | 2060P 3060P 3260P 6360P | 851XP-IHL 1251XP-IHL | 3060P-IHL, 3260P-IHL, 6360P-IHL | 851XP 1251XP | 2060P 3060P 3260P 6360P | CC500, 800, 1200, 1400, & 2000 P-HL. CC600F, 900F, 1300F, 2500F, & 4000FP-HL | 851XP-IHL 1251XP-IHL | 3060P-IHL, 3260P-IHL, 6360P-IHL |
CC500, 800, 1200, 1400, & 2000 P-HL2. CC600F, 900F, 1300F, 2500F, & 4000F P-HL2 |
|
| GROUP D: Gasoline, hexane, butane, naphtha, propane, toluene, isoprene, alcohol, acetone, lacquer solvent, natural gas, etc. | 851XP 1251XP | 2060P 3060P 3260P 6360P | 851XP-IHL 1251XP-IHL | 3060P-IHL, 3260P-IHL, 6360P-IHL | 851XP 1251XP | 2060P 3060P 3260P 6360P | CC500, 800, 1200, 1400, & 2000 P-HL. CC600F, 900F, 1300F, 2500F, & 4000FP-HL | 851XP-IHL 1251XP-IHL | 3060P-IHL, 3260P-IHL, 6360P-IHL |
CC500, 800, 1200, 1400, & 2000 P-HL2. CC600F, 900F, 1300F, 2500F, & 4000F P-HL2 |
|
| CLASS 2 | |||||||||||
| GROUP E: Flammable metal powders, etc. | (S)851XP 1251XP | 2060P 3060P 3260P 6360P | No | No | (S) 851XPE 1251XPE | 2060P 3060P 3260P 6360P | No | No | No |
No |
|
| GROUP F: Carbon black, coal dust, coke dust, etc. | 851XP 1251XP | 2060P 3060P 3260P 6360P | No | No | 851XP 1251XP | 2060P 3060P 3260P 6360P | No | No | No |
No |
|
| GROUP G: Flour, starch, grain dust, etc. | 851XP 1251XP | 2060P 3060P 3260P 6360P | No | No | 851XP 1251XP | 2060P 3060P 3260P 6360P | No | No | No |
No |
|